Neurology · Speech therapy
Barnes-Jewish Hospital Stroke Dysphagia Screen calculator
Enter the published formula inputs below to calculate and interpret this score.
Clinical inputs
Allowed range: 3–15 points
A score below 13 fails this item. Exactly 13 does not.
Result
1 field remaining
Anyone can run this calculator. Sign in to save, favourite, or send the result.
Ruqelo is AI and can make mistakes. Check important information.
Clinical inputs
- Glasgow coma scale (points)Accepted range: 3 to 15
- Facial asymmetry or weakness
- Tongue asymmetry or weakness
- Palatal asymmetry or weakness
- Aspiration signs on the 3-ounce water swallow
Primary source
Edmiaston J et al. A simple bedside stroke dysphagia screen, validated against videofluoroscopy, detects dysphagia and aspiration with high sensitivity. J Stroke Cerebrovasc Dis. DOI: 10.1016/j.jstrokecerebrovasdis.2013.06.030. PMID: 23910514. The screen fails when any of five items is abnormal: Glasgow Coma Scale below 13, facial asymmetry or weakness, tongue asymmetry or weakness, palatal asymmetry or weakness, or signs of aspiration on the 3-ounce water swallow. A pass requires all five to be normal. Against videofluoroscopy, sensitivity for dysphagia was 94% and for aspiration 95%. The same fail-if-any rule is in Edmiaston J et al. Am J Crit Care. 2010. PMID: 19875722. (2014)
View source